DINION 5000 AN
VBN-5085
en Installation Manual
DINION 5000 AN
Table of Contents | en
3
Table of Contents
Safety
Safety precautions
System ground/Safety ground
Important safety instructions
Important notices
FCC information
UL certification
Bosch notice
Introduction
Features
Installation
Unpacking
Connection and mounting
Power connection
Low voltage cameras
High voltage cameras
Video connections
Output Video signal
Alarm and relay connector
Lens mounting
Back focus adjustment
Mounting the camera
Configuration
Menus
Top level menus
Menu navigation
Pre-defined modes
Day/Night switching
Camera control communication (Bilinx)
Main menu structure
Mode submenu
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
4
en | Table of Contents
DINION 5000 AN
Exposure submenu
Day/Night submenu
Enhance / Dynamic Engine submenu
Color submenu
VMD submenu
Image Adjustment submenu
Install menu structure
Language submenu
Lens Wizard submenu
Synchronization submenu
Alarm I/O submenu
Connections submenu
Test signal submenu
Camera ID submenu
Privacy masking submenu
Flip submenu
Defaults submenu
Troubleshooting
Resolving problems
Customer service
Maintenance
Repairs
Transfer and disposal
Technical Data
Specifications
Dimensions
Accessories
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Safety | en
5
1
Safety
1.1
Safety precautions
DANGER!
High risk: This symbol indicates an imminently hazardous
situation such as "Dangerous Voltage" inside the product.
If not avoided, this will result in an electrical shock, serious
bodily injury, or death.
WARNING!
Medium risk: Indicates a potentially hazardous situation.
If not avoided, this could result in minor or moderate bodily
injury.
CAUTION!
Low risk: Indicates a potentially hazardous situation.
If not avoided, this could result in property damage or risk of
damage to the unit.
1.2
System ground/Safety ground
System (video) ground is indicated by the symbol
.
.
Safety (power) ground is indicated by the symbol
The system ground is only used to comply with safety standards
or installation practices in certain countries. Bosch does not
recommend connecting system ground to safety ground unless
it is explicitly required. However, if the system ground and
safety ground are connected and grounding loops are causing
interference in the video signal, use an isolation transformer
(available separately from Bosch).
CAUTION!
Connecting System ground to Safety ground may result in
ground loops that can disrupt the CCTV system.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
6
en | Safety
DINION 5000 AN
1.3
Important safety instructions
Read, follow, and retain for future reference all of the following
safety instructions. Heed all warnings on the unit and in the
operating instructions before operating the unit.
1. Cleaning - Generally, using a dry cloth for cleaning is
sufficient but a moist, fluff-free cloth or leather shammy
may also be used. Do not use liquid cleaners or aerosol
cleaners.
2. Heat Sources - Do not install the unit near any heat
sources such as radiators, heaters, stoves, or other
equipment (including amplifiers) that produce heat.
3. Water - Never spill liquid of any kind on the unit.
4. Lightning - Take precautions to protect the unit from
power and lightning surges.
5. Controls adjustment - Adjust only those controls specified
in the operating instructions. Improper adjustment of
other controls may cause damage to the unit.
6. Power sources - Operate the unit only from the type of
power source indicated on the label.
7. Servicing - Unless qualified, do not attempt to service this
unit yourself. Refer all servicing to qualified service
personnel.
8. Replacement parts - Use only replacement parts specified
by the manufacturer.
9. Installation - Install in accordance with the manufacturer's
instructions and in accordance with applicable local codes.
10. Attachments, changes or modifications - Only use
attachments/accessories specified by the manufacturer.
Any change or modification of the equipment, not
expressly approved by Bosch, could void the warranty or,
in the case of an authorization agreement, authority to
operate the equipment.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Safety | en
7
1.4
Important notices
Disposal - Your Bosch product was developed and
manufactured with high-quality material and components that
can be recycled and reused. This symbol means that
electronic and electrical appliances, which have reached the
end of their working life, must be collected and disposed of
separately from household waste material. Separate collecting
systems are usually in place for disused electronic and
electrical products. Please dispose of these units at an
environmentally compatible recycling facility, per European
Directive 2002/96/EC
WARNING!
Power disconnect for high voltage versions: A unit has power
supplied whenever the power cord is inserted into the power
source. The power cord plug is the main power disconnect for
the unit. For pluggable equipment, install the socket outlet near
the equipment so it is easily accessible.
WARNING!
All-pole power switch: Incorporate an all-pole power switch,
with a contact separation of at least 3 mm in each pole, into the
electrical installation of the building.
CAUTION!
Fuse rating: The branch circuit protection must be secured with
a maximum fuse rating of 16 A. This must be in accordance with
NEC800 (CEC Section 60).
CAUTION!
The Low Voltage power supply unit must comply with EN/UL
60950. The power supply must be a SELV-LPS unit or a SELV -
Class 2 unit (Safety Extra Low Voltage - Limited Power Source).
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
8
en | Safety
DINION 5000 AN
1.5
FCC information
FCC & ICES Information
(U.S.A. and Canadian Models Only)
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
–
–
reorient or relocate the receiving antenna;
increase the separation between the equipment and
receiver;
–
–
connect the equipment into an outlet on a circuit different
from that to which the receiver is connected;
consult the dealer or an experienced radio/TV technician
for help.
Intentional or unintentional modifications, not expressly
approved by the party responsible for compliance, shall not be
made. Any such modifications could void the user's authority to
operate the equipment. If necessary, the user should consult
the dealer or an experienced radio/television technician for
corrective action.
The user may find the following booklet, prepared by the
Federal Communications Commission, helpful: How to Identify
and Resolve Radio-TV Interference Problems. This booklet is
available from the U.S. Government Printing Office,
Washington, DC 20402, Stock No. 004-000-00345-4.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Safety | en
9
1.6
UL certification
Disclaimer
Underwriter Laboratories Inc. ("UL") has not tested the
performance or reliability of the security or signaling aspects of
this product. UL has only tested fire, shock and/or casualty
hazards as outlined in UL's Standard(s) for Safety for Information
Technology Equipment, UL 60950-1. UL Certification does not
cover the performance or reliability of the security or signaling
aspects of this product.
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR
CERTIFICATIONS WHATSOEVER REGARDING THE
PERFORMANCE OR RELIABILITY OF ANY SECURITY OR
SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT.
1.7
Bosch notice
More information
For more information please contact the nearest Bosch Security
Systems location or visit www.boschsecurity.com
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
10 en | Introduction
DINION 5000 AN
2
Introduction
2.1
Features
The DINION 5000 Day/Night WDR camera is a high-
performance, smart, surveillance color camera. It uses a wide
dynamic range 960H CCD sensor for outstanding picture
performance.
The camera is easy to install and ready to use, and offers the
best solution for demanding scene conditions. Features
include:
–
–
–
–
–
–
–
–
–
–
–
–
–
1/3-inch 960H CCD sensor with wide dynamic range
True Day/Night performance with switchable IR filter
720TVL sensor resolution
High Dynamic Range
Privacy zones
Detail enhancement
Bilinx (bi-directional coaxial communication)
Wide operating temperature range
Lens wizard
Six pre-programmed operation modes
Dynamic noise reduction
Multiple language on-screen display
Built-in test pattern generator
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Installation | en 11
3
Installation
3.1
Unpacking
Unpack carefully and handle the equipment with care.
The packaging contains:
–
–
–
–
–
–
–
DINION 5000 camera
CCD protection cap (mounted on camera)
Alarm I/O connector
Power connector
Important safety instructions
Quick install instructions
CD-ROM
–
Installation instructions
If equipment has been damaged during shipment, repack it in
the original packaging and notify the shipping agent or supplier.
WARNING!
Installation should only be performed by qualified service
personnel in accordance with the National Electrical Code
NEC800 (CEC Section 60) or applicable local codes.
CAUTION!
The camera module is a sensitive device and must be handled
carefully.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
12 en | Connection and mounting
DINION 5000 AN
4
Connection and mounting
CAUTION!
Before proceeding, disconnect the power from the power
supply cable. Ensure that the voltage of the unit matches the
voltage and type of the power supply being used.
4.1
Power connection
4.1.1
Low voltage cameras
1
2
3
5 mm
Figure 4.1 Low voltage power connection
Connect power from a 24 VAC or 12 VDC class 2 power supply
as follows:
–
Use AWG16 to 22 stranded wire or AWG16 to 26 solid
wire; cut back 5 mm (0.2 in) of insulation.
Remove the 3-pole connector from the camera body.
Loosen the screws and insert the wires.
–
–
Note
The central connection for System (video) ground is
optional. Connecting System ground to Safety ground may
result in ground loops that can disrupt the CCTV system.
–
Tighten the screws and reconnect the 3-pole connector to
the camera.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Connection and mounting | en 13
Note
For a DC supply the polarity is important. Incorrect polarity
does not damage the camera but it will not switch on. For an
AC supply maintain a consistent wiring polarity in multiple
camera systems to help avoid potential camera video rolling.
4.1.2
High voltage cameras
1
2
3
4
5
6
Figure 4.2 High voltage power connection
Connect the power cable of a high voltage camera to a 230 VAC
power supply outlet.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
14 en | Connection and mounting
DINION 5000 AN
4.2
Video connections
VIDEO
Video BNC
AL
ARM
1
2
3
4
5
6
Figure 4.3 BNC connectors
4.2.1
Output Video signal
The camera has a BNC connector to connect the video coax
cable with a male BNC connector. A UTP adapter (VDA-455UTP)
is available as an optional accessory to allow a UTP video cable
to be connected to the BNC connector.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Connection and mounting | en 15
4.3
Alarm and relay connector
ALARM
1
2
3
4
5
6
5 mm
(0.2 in)
Figure 4.4 Alarm and relay connector pins
Pin
1
Alarm socket
Alarm in
2
not used
3
Relay out contact 2
Alarm in ground
not used
4
5
6
Relay out contact 1
–
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
Alarm output relay switching capability: Max voltage 30VAC
or +40 VDC. Max 0.5 A continuous, 10 VA.
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled
with 22 kOhm pull-up to +3.3 V.
–
–
–
–
Alarm in: configurable as active low or active high.
Max. 42 V allowed between camera ground and each of the
relay pins.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
16 en | Connection and mounting
DINION 5000 AN
4.4
Lens mounting
The camera accepts CS-mount lenses. C-mount lenses can be
mounted using the lens adapter ring. DC-iris lenses are
recommended for the best picture performance.
CAUTION!
To avoid damaging the CCD sensor when using a C-mount lens,
make sure the supplied lens adapter ring is mounted onto the
camera before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.
Bosch
Bosch
Figure 4.6 Lens connector
Figure 4.5 Mounting a lens
Pin Video iris lens
DC iris lens
1
2
3
4
Supply (11.5V 0.5, 50mA max.)
Damp -
Damp +
Drive +
Drive -
Not used
Video signal 1Vpp 1kOhm
Ground
Note
If a short circuit is detected on the lens connector, the on-
screen display (OSD) failure message LENS SHORT CIRCUIT is
shown. The lens circuit is automatically disabled to avoid
internal damage. Remove the lens connector and check the pin
connections.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Connection and mounting | en 17
4.5
Back focus adjustment
To optimize picture sharpness in both bright and low-level
lighting, adjust the back focus. Use the camera's unique Lens
Wizard. This ensures that the object of interest always remains
in focus, even when focusing at the maximum lens iris opening
(for example, at night).
–
When back focusing varifocal lenses, adjust to obtain a
sharp picture in both wide-angle and tele positions for
both far and near focus.
–
When back focusing zoom lenses, ensure the object of
interest remains in focus throughout the entire zoom range
of the lens.
To adjust back focus:
1. Open the slide door panel at the side of the camera.
1. Unlock the back focus locking button.
2. Press and hold the center key for more than 1 second until
the Install menu appears.
3. Select Len Wizard and move cursor to the Set Back Focus
Now item.
4. Turn the back focus adjustment as required.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
18 en | Connection and mounting
DINION 5000 AN
5. Lock the back focus locking button.
6. Press and hold the center key for more than 1 second until
all the menus disappear.
7. Close the side door panel.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Connection and mounting | en 19
4.6
Mounting the camera
The camera can be mounted either from the top or from the
bottom (1/4" 20 UNC thread). The bottom mounting is isolated
from ground to prevent ground loops.
Figure 4.7 Mounting a camera
CAUTION!
Do not point the camera/lens into direct sunlight as this may
damage the sensors.
Note:
A wide range of accessories is available for indoor and outdoor
mounting.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
20 en | Configuration
DINION 5000 AN
5
Configuration
The camera normally provides an optimal picture without the
need for further adjustments. Advanced set-up options are
available in a menu system for getting the best results under
special circumstances.
The camera implements your changes immediately so that
before and after settings are easily compared.
5.1
Menus
5.1.1
Top level menus
There are two upper level menus: a Main menu and an Install
menu. The menus have functions that can be selected directly
or submenus for more detailed set-up.
–
To access the Main menu, press the menu/select button
(center) for less than 1 second. The Main menu appears on
the monitor. The Main menu allows you to select and set-
up the picture enhancement functions. If you are not happy
with your changes, you can always recall the default values
for the mode.
–
The camera also has an Install menu in which the
installation settings can be set. To access the Install menu,
press the menu/select button (center) for longer than 2
seconds.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 21
5.1.2
Menu navigation
Five keys, located behind the side door panel, are used for
navigating through menu system.
Figure 5.1 Side panel door
Figure 5.2 Menu/select key
Up key
Menu/Select key (center)
Right key
Down key
Left key
Figure 5.3 Navigation
–
–
Use the up or down keys to scroll through a menu.
Use the left or right keys to move through options or to set
parameters.
–
–
When in a menu, quickly double-press the menu/select key
to restore the selected item to its factory default.
To close all menus at once hold down the menu/select key
until the menu display disappears or continually select the
Exit item.
Some menus automatically close after about two minutes; other
menus have to be closed manually.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
22 en | Configuration
DINION 5000 AN
5.2
Pre-defined modes
There are six pre-defined modes with settings to make
configuration easier. You can select one of the six pre-defined
modes in the Install/Mode submenu. The modes are defined as
follows;
1. 24-hour
Default installation mode to provide stable pictures over a
24-hour period. These settings are optimized for out-of-
the-box installation.
2. Traffic
Capture high-speed objects using default shutter in
variable lighting conditions.
3. Low light
Provide extra enhancement, such as AGC and SensUp to
make usable pictures in low-light conditions.
4. Smart BLC
Settings optimized to capture details in high contrast and
extremely bright-dark conditions.
5. Low noise
Enhancements are set to reduce picture noise. Useful for
conditional refresh DVR and IP storage systems because
reducing noise reduces the amount of storage required.
6. Vibrant
This mode has enhanced contrast, sharpness and
saturation.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 23
5.3
Day/Night switching
The camera is equipped with a motorized IR filter. The
mechanical IR filter can be removed in low-light or IR
illuminated applications by software configuration settings.
If Auto switching mode is selected, the camera automatically
switches the filter depending on the observed light level. The
switching level is programmable. In Auto switching mode the
camera prioritizes motion (the camera gives sharp images
without motion blur as long as the light level permits) or color
(the camera gives color pictures as long as the light level
permits). The camera recognizes IR illuminated scenes to
prevent unwanted switching to color mode.
There are four different methods of controlling the IR filter:
–
–
–
–
via an alarm input,
via Bilinx communication,
automatically, based on the observed light levels, or
as part of the programmable mode profile.
5.4
Camera control communication (Bilinx)
This camera is equipped with a coaxial communications
transceiver (also referred to as Bilinx). In combination with VP-
CFGSFT, the camera setting can be changed from any point
along the coaxial cable. All menus can be accessed remotely
giving full control of the camera. With this method of
communication it is also possible to disable the local keys on
the camera.To avoid loss of communication on an installed
camera, the Communication On/Off selection is not available
while using remote control. This function can only be accessed
with the camera buttons. Bilinx communications can only be
disabled using the buttons on the camera.
Disabled camera buttons
When the Bilinx communications link is active, the buttons on
the camera are disabled.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
24 en | Configuration
DINION 5000 AN
5.5
Main menu structure
Item
Selection
Submenu
Submenu
Submenu
Submenu
Submenu
Submenu
Submenu
Description
Mode
Sets up operating modes 1 to 6
Exposure control
Exposure
Day/Night
Enhance
Color
Day/Night for color/mono operation
Picture enhancement and performance
White balance and color rendition
Video motion detection
VMD
Image
Sets up digital zoom or digital image
stabilization
Adjustment
5.5.1
Mode submenu
Item
Selection
Description
Mode
1 to 6
Selects operating mode.
Mode name (11 characters maximum)
Mode ID
Alphanumeric
Copy active
mode
Available
mode
Copies current mode settings to the
mode number selected.
numbers
Mode
Submenu
Restores camera to the factory default
settings.
Defaults
EXIT
Returns to main menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 25
5.5.2
Exposure submenu
Item
Selection
Description
ALC level
-15 to +15
Selects the video level range. A
positive value is more useful for low-
light conditions; a negative value is
more useful for very bright
conditions.
Some ALC adjustment may improve
scene content when Smart BLC is
enabled.
ALC speed
Shutter
Slow,
Adjusts the speed of the video level
control loop. For most scenes it
should remain at the default value.
medium, fast
AES, FL, Fixed
AES (auto-shutter) - the camera
automatically sets the optimum
shutter speed.
FL - flickerless mode avoids
interference from light sources
(recommended for DC-iris lenses
only).
FIXED - allows a user defined shutter
speed.
Default (AES)
shutter
1/50 (PAL)
1/60 (NTSC),
1/100 (PAL)
1/120 (NTSC),
1/250,
In DEFAULT (AES) mode, the camera
tries to maintain the selected shutter
speed as long as the light level of the
scene is high enough.
or
Fixed shutter
In Fixed mode, selects shutter
speed.
1/500,
1/1000,
1/2000,
1/4000,
1/10K,
1/100K
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
26 en | Configuration
DINION 5000 AN
Item
Selection
Description
Actual shutter
Displays the actual shutter value
from the camera to help compare
lighting levels and optimum shutter
speed during set-up.
Gain control
On, Fixed
0 to 40 dB
On - the camera automatically sets
the gain to the lowest possible value
needed to maintain a good picture.
Fixed - sets Fixed AGC value.
Maximum AGC
or
Selects the maximum value the gain
can have during AGC operation.
Selects the gain setting for Fixed
gain operation (0 is no gain).
Fixed AGC
Actual AGC
Displays the actual AGC value from
the camera to help compare gain
level with lighting levels and picture
performance.
SensUp
Off, 2x,
Selects the factor by which the
sensitivity of the camera is
increased.
Dynamic
3x, …, 10x
When active, some noise or spots
may appear in the picture. This is
normal camera behavior. It may also
cause motion blur on moving
objects.
EXIT
Returns to main menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 27
5.5.3
Day/Night submenu
Item
Selection
Description
Day/Night
Auto, Color,
Auto - the camera switches the IR cut-
off filter on and off depending on the
scene illumination level.
Monochrome
Color - the camera always produces a
color signal regardless of light levels.
Monochrome - the IR cut-off filter is
removed, giving full IR sensitivity.
Switch level
-15 to +15
Sets the video level in Auto mode at
which the camera switches to
monochrome operation.
A low (negative) value means that the
camera switches to monochrome at a
lower light level. A high (positive) value
means that the camera switches to
monochrome at a higher light level.
Switch delay
Priority
1, 2, 3, 5, 10,
20, 30, 60,
120, 240 s
Sets the evaluation time in Auto mode
for day to night transitions.
Motion, Color
In AUTO mode:
Color - the camera gives a color image
as long as the light level permits.
Motion - the camera avoids motion blur
as long as the light level permits (it
switches to monochrome earlier than it
would with Color priority).
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
28 en | Configuration
DINION 5000 AN
Item
Selection
Description
IR contrast
(mono)
Enhanced,
Normal
Enhanced - the camera optimizes
contrast in applications with high IR
illumination levels. Select this mode
for IR (730 to 940 nm) light sources
and for scenes with grass and green
foliage.
Normal - the camera optimizes contrast
in mono applications with visible light
illumination.
IR
0 to +15
On, Off
Enter the strength of the external IR
illumination to determine the night to
day transition moment. 0 is no IR
illuminator; +15 is very strong
illumination.
illumination
(mono)
Color burst
(mono)
Off - the color burst in the video signal
is switched Off in monochrome mode.
On - the color burst remains active
even in monochrome mode (required
by some DVRs and IP encoders).
EXIT
Returns to main menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 29
5.5.4
Enhance / Dynamic Engine submenu
Item
Selection
Description
Dynamic
Off,
Off: - turns off all automatic scene
detail and enhancements (only
recommended for testing).
Engine
XF DYNAMIC,
HDR,
Smart BLC
XF DYNAMIC: - extra internal
processing is enabled for enhancing
the visibilty.
HDR: - adds dual sensor exposure to
the XF DYNAMIC features. In harsh
lighting conditions, pixels from each
exposure are mixed to give a more
detailed image.
Smart BLC: - BLC window and
weighting factor are automatically
defined. Camera dynamically adjusts
these for changing light conditions.
Contrast
Low,
Increases the contrast at medium
brightness levels.
Enhancement
Medium,
High
Select Low for high contrast scenes.
Select High for low contrast scenes
(e.g. fog).
Sharpness
-15 to +15
Adjusts the sharpness of the picture. 0
corresponds to the default position.
A low (negative) value makes the
picture less sharp. Increasing
sharpness brings out more detail.
Extra sharpness can enhance the
details of license plates, facial features
and the edges of certain surfaces.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
30 en | Configuration
DINION 5000 AN
Item
Selection
Description
3D-NR
Off,
Automatically reduces the noise in the
picture.
Low,
Medium,
High
This may cause some motion blur on
exceptionally fast moving objects
immediately in front of the camera.
This can be corrected by widening the
field of view or lowering the selection
value.
2D-NR
Off,
Automatically reduces the noise in the
picture.
Low,
Medium,
High
A high selection may cause blur.
A lower selection improves sharpness
at the cost of more noise
Peak White
Invert
On, Off
Use Peak White Invert to reduce glare
from the CRT/LCD display.
Use in ANPR/LPR applications to
reduce headlight glare.
(Test on-site to ensure that it does
benefit the application and is not
distracting for operators of the security
system.)
EXIT
Returns to main menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 31
5.5.5
Color submenu
Item
Selection
Description
White balance
ATW indoor,
ATW Outdoor,
ATW hold,
Manual
ATW - Auto tracking white balance
allows the camera to constantly
adjust for optimal color
reproduction.
ATW hold - Puts the ATW on hold and
saves the color settings.
Manual - the Red and Blue gain can
be manually set to a desired position.
Speed
Fast,
Adjusts the speed of the white
balance control loop.
Medium,
Slow
Red gain
Blue gain
Saturation
-50 to +50
-50 to +50
-15 to +5
Manual and ATW hold - adjusts the
Red gain.
Manual and ATW hold - adjusts the
Blue gain.
Adjusts the color saturation. -15
gives a monochrome image; 0 gives
the default saturation; +15 gives the
most saturation.
EXIT
Returns to main menu.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
32 en | Configuration
DINION 5000 AN
5.5.6
VMD submenu
Item
Selection
Description
VMD area
Submenu
Select 1 of the 4 areas to enter the
area set-up menu to define the
detection area.
VMD mode
Off, Silent,
OSD
Off - Video Motion Detection (VMD) is
off.
Silent - video motion generates silent
alarm.
OSD - video motion generates on-
screen text message alarm.
VMD
0 to 127
Sets the sensitivity for motion to the
desired level. The longer the white bar,
the more motion is required to acitvate
the VMD alarm. Motion above this level
activates alarm.
sensitivity
OSD alarm
text
Alphanumeric
Text for on-screen display alarm (16
characters maximum).
EXIT
Returns to main menu.
Selecting an area for VMD masking
To set-up an area for VMD masking, access the area menu by
selecting the VMD Area option from the VMD menu. Upon
entering the Area menu, the current area is displayed with the
upper left corner flashing. The flashing corner of the image can
be moved with the Up, Down, Left, Right arrow keys. Pressing
the Select key moves the flashing cursor to the opposite corner,
which can now be moved. Pressing Select again freezes the
area and exits the area menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
34 en | Configuration
DINION 5000 AN
5.6
Install menu structure
Item
Selection
Description
Language
Submenu
Select on-screen display (OSD)
language
Lens Wizard
Submenu
Submenu
Submenu
Select to optimize the camera-lens
combination backfocus point.
Synchroniza-
tion
Sets synchronization parameters
Alarm I/O
Program the alarm input and output
functionality.
Connections
Test signals
Camera ID
Submenu
Submenu
Submenu
Submenu
Connection parameters
Test patterns and texts
Select to access ID submenu
Sets up a masking area
Privacy
masking
Flip
Submenu
Submenu
Selects flip submenu
Default ALL
Returns all settings for all modes to
factory defaults
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 35
5.6.1
Language submenu
Item
Selection
Description
Language
English
Displays the menus on the OSD in the
chosen language.
Spanish
French
German
Portuguese
Russian
Simplified
Chinese
EXIT
Returns to Install menu.
5.6.2
Lens Wizard submenu
Item
Selection
Description
Lens type
Manual, DC-
iris
Select the matching lens type to force
the camera to the correct lens mode.
DC- iris setup
Open,
Selects the type of control for DC-iris
lens.
Close, Auto
Open - the DC-iris is fixed to open.
Close - the DC-iris is fixed to close.
Auto - the aperture of the lens is
adjusted automatically.
DC-iris speed
0,1,2…255
Adjusts the convergence speed of DC-
iris.
DC-iris
The convergence speed is
calibration
automatically determined using the
built-in calibration mechanism.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
36 en | Configuration
DINION 5000 AN
Item
Selection
Description
Set Backfocus
now
Select to fully open the iris. Follow the
instructions below for setting the
backfocus for your particular lens type.
After focusing the object of interest
remains in focus under bright and low
light conditions.
EXIT
Returns to Install menu.
Adjustment procedure DC-iris Lens
1. Unlock the back focus locking button.
2. Access the Lens Wizard menu.
3. Set Back Focus Now is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Adjustment procedure Manual-iris Lens
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
5. Adjust lens opening to suit scene.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 37
5.6.3
Synchronization submenu
Item
Selection
Description
Synchroniza-
Internal
Internal - for free running camera
operation.
tion
Line lock
Line lock - to lock to the AC power
supply
Vertical phase
EXIT
0, 1, … 359
Adjusts the vertical phase offset (when
in LINE LOCK mode and a valid power
supply frequency is detected).
Returns to Install menu.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
38 en | Configuration
DINION 5000 AN
5.6.4
Alarm I/O submenu
Item
Selection
Description
Input
None, high,
low
Select none to disable the alarm input.
Select active-high or active-low for the
alarm input connector.
Input action
Output
None,
Selects the operating mode of the
Mode 1 to 6,
Night mode
camera when the alarm input is active.
Normally
open,
Selects the relay output mode.
Normally
closed
Output action
VMD,
VMD: - output relay closes on VMD
alarms.
Ext. device,
Night mode,
Filter toggle
External device: - make the output
relay available to remote
communication devices.
Night mode: - output relay closes when
camera is in monochrome mode.
Filter toggle: - output relay closes just
before the IR filter starts moving and
opens when video level has stabilized
(2 to 3 seconds)
EXIT
Returns to Install menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 39
5.6.5
Connections submenu
Item
Selection
Description
Bilinx Comms.
On, Off
If Off, Bilinx communications is
disabled.
Camera
buttons
Enable,
disable
Enable or disable the camera buttons
from working.
Cable
Off, Default,
RG59, RG6
Cable compensation is used to avoid
the need for amplifiers in long distance
coaxial connections up to 1000 m
(3000 ft). For optimum results select
the coaxial cable type used or, if
unknown, select default.
compensation
Compensation
level
0,1,2 . . .+15
Sets the level of cable compensation
EXIT
Returns to Install menu.
5.6.6
Test signal submenu
Item
Selection
Description
Show camera
Off, On
Select On to overlay the camera ID on
the video test signal.
ID
Test pattern
Color bars,
Raster,
Select the desired test pattern to help
installation and fault-finding.
Impulse,
Cross
Impulse,
Crosshatch
EXIT
Returns to Install menu.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
40 en | Configuration
DINION 5000 AN
5.6.7
Camera ID submenu
Item
Selection
Description
Camera ID
Enter a 17-character camera name. Use
Left/Right to change position in the
string; use up/down to select
character. Use Select to exit.
Display ID pos.
Off, Top left,
Top right,
Select the screen position of the
camera ID.
Bottom left,
Bottom right
Camera ID
border
On, Off
Displays a grey border behind the
camera ID to make it easier to read.
MAC address
Shows MAC address (factory set,
cannot be changed).
Ticker bars
On, Off
The ticker bar moves continuously to
show that the image is live and not
frozen or played back.
Mode ID pos.
Off, Top left,
Top right,
Camera mode is displayed on the
screen in the selected position.
Bottom left,
Bottom right
EXIT
Returns to Install menu.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Configuration | en 41
5.6.8
Privacy masking submenu
Item
Selection
Description
Mask
1 to 15
15 different areas can be masked.
Selects pattern for all masks.
Pattern
Black, Grey,
White, Noise
Active
On, Off
On, Off
Submenu
Turns each of the masks on or off.
Turns mosaic on or off.
Mosaic
Window
Select to open a window in which to
define the mask area.
Selecting an area for privacy masking
To set-up an area for privacy masking, access the area menu by
selecting the Area option from the privacy masking menu. Upon
entering the Area menu, the current area is displayed with the
upper left corner flashing. The flashing corner of the image can
be moved with the Up, Down, Left, Right arrow keys. Pressing
the Select key moves the flashing cursor to the opposite corner,
which can now be moved. Pressing Select again freezes the
area and exits the area menu.
5.6.9
Flip submenu
Item
Selection
Description
Flip
Off
Selects the flip mode.
horizontal
Vertical
Both
EXIT
Returns to Install menu.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
42 en | Configuration
DINION 5000 AN
5.6.10
Defaults submenu
Item
Selection
Description
Restore All
No, Yes
Restores all settings of the six modes
to their default (factory) values. Select
YES then press the Menu/Select
button to restore all values.
When completed the message
RESTORED! is shown.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Troubleshooting | en 43
6
Troubleshooting
6.1
Resolving problems
The following table is intended to help you identify the causes
of malfunctions and correct them when possible.
Malfunction
Possible causes
Solution
No image
Defective camera.
Connect a local monitor
to the camera and check
the camera function.
transmission to
remote location.
Faulty cable connections. Check all cables, plugs,
contacts and
connections.
Incorrect cable
connections.
When using DC power
ensure that polarity is
correct.
No connection
The unit's configuration.
Faulty installation.
Check all configuration
parameters.
established, no
image transmission.
Check all cables, plugs,
contacts and
connections.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
44 en | Troubleshooting
DINION 5000 AN
6.2
Customer service
If you cannot resolve a fault, please contact your supplier or
system integrator, or contact Bosch Security Systems
Customer Service directly.
The Installer should write down all information regarding the
unit so that it can be referenced for warranty or repair. The
version numbers of the firmware and other status information
can be seen when the unit starts or by opening the Install
menu. Note down this information and the information found
on the camera label before contacting customer service.
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Maintenance | en 45
7
Maintenance
7.1
Repairs
CAUTION!
Never open the casing of the camera. The unit does not contain
any user serviceable parts. Ensure that all maintenance or
repair work is performed only by qualified personnel (electrical
engineering or network technology specialists). If in doubt,
contact your dealer's technical service center.
7.1.1
Transfer and disposal
The camera should only be passed-on together with this
installation guide. The unit contains environmentally hazardous
materials that must be disposed of according to law. Defective
or superfluous devices and parts should be disposed of
professionally or taken to your local collection point for
hazardous materials.
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
46 en | Technical Data
DINION 5000 AN
8
Technical Data
8.1
Specifications
Type number
Standard
VBN-5085-C11
PAL
VBN-5085-C21
NTSC
VBN-5085-C51
PAL
Active pixels
976 x 582
976 x 494
976 x 582
230 VAC 50 Hz
Rated supply
voltage
+12 VDC
+12 VDC
24 VAC (50 Hz)
24 VAC (60 Hz)
All versions
Imager
1/3-inch 960H CCD
Resolution
720TVL sensor resolution
Sensitivity
(30IRE)
<0.04 lux
<0.02 lux (in monochrome mode)
SNR
> 54 dB
Video output
1 Vpp, 75 Ohm
Internal, Line Lock
Synchroniza-
tion
Shutter
Auto (1/60 [1/50] to 1/100000)
Selectable, fixed, flickerless, default
Day/Night
Sens Up
AGC
Color, Mono, Auto
Adjustable from Off to 10x
AGC On or Off (0 - 40 dB) selectable
Dynamic engine XF Dynamic, HDR, Smart BLC
Dynamic Range 94 dB
Dynamic Noise
Reduction
3D-NR, 2D-NR
Sharpness
Sharpness enhancement level selectable
ATW indoor, ATW outdoor, ATW hold and manual
Low, Medium, High
White Balance
Contrast
Enhancement
Lens type
Manual or DC iris
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
DINION 5000 AN
Lens mount
Technical Data | en 47
CS compatible, C-mount compatible with optional
adapter ring
Test pattern
generator
Color bar, Raster, Impulse, Cross Impulse, Cross hatch
Video Motion
Detection
(VMD)
4 areas, fully programmable
Privacy Masking 15 independent areas, fully programmable; black, white,
grey, noise
E-zoom
Up to 16x
On/Off
Digital Image
Stabilizer
Communication Two-way Bilinx (bi-directional)
Languages
(OSD)
English, Spanish, French, German, Portuguese, Russian,
Simplified Chinese
Modes
6 programmable (preset) modes: 24-hour, Traffic, Low-
light, Smart BLC, Low noise, Vibrant
Peak White
Invert
Suppresses highlights in scenes
Power
12 VDC 360 mA24 VAC 330 mA120-240 VAC 60 mA
58 x 66 x 122 mm (2.28 x 2.60 x 4.80 in) without lens
500 g (1.10 lb) without lens
consumption
Dimensions
(H x W x L)
Weight
(12 VDC/
24 VAC)
Weight
600 g (1.32 lb) without lens
(230 VAC)
Tripod mount
Bottom (isolated) and top 1/4" 20 UNC
-20 °C to +55 °C (-4 °F to +131 °F)
Operating
temperature
Controls
OSD with softkey operation
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
DINION 5000 AN
Technical Data | en 49
8.1.2
Accessories
–
–
–
–
Indoor mounting brackets
Outdoor environmental housings
Lenses (varifocal, fixed and motorized zoom)
Bilinx communication interface box and software
Contact a Bosch representative in your area for the latest
available accessories or visit our website at
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
50 en | Technical Data
DINION 5000 AN
AM18-Q0644 | v1.0 | 2013.03
Installation Manual
Bosch Security Systems
|