Introduction
1.3.3 Operations
Data packets entering through the front panel of a SmartSwitch
interface module in the 7C03 MMAC SmartSwitch are converted
by the module’s hardware into frames that have a common
“canonical” format. Canonical frames are forwarded along the
7C03’s SmartSwitch Bus to the 7X00 Module in slot one. The
configuration of the 7X00 Module (either traditional switch or
SecureFast Packet Switch) determines the manner in which
canonical frames are processed.
When operating as a traditional switch (a store-and-forward
switch using the 802.1d Spanning Tree protocol), the 7X00
Module’s SmartSwitch searches for the canonical frame’s
destination address in the module’s connection table. If the
canonical frame’s destination address is found in the connection
table, the frame is forwarded to that specific destination via the
7C03’s SmartSwitch Bus. If the canonical frame’s destination
address is not found in the connection table, the frame is flooded to
all of the SmartSwitch interface modules via the 7C03’s
SmartSwitch Bus.
When operating as a SecureFast Packet Switch, the 7X00 Module’s
SmartSwitch searches for the canonical frame’s destination
address-source address (DA-SA) pair and receive port in the
module’s connection table. If the canonical frame’s entry is found
in the connection table, the frame is forwarded to a specific
destination via the 7C03’s SmartSwitch Bus. If the canonical
frame’s entry is not found in the connection table, a request is sent
to the system’s Virtual Network Services (VNS). The VNS checks
its virtual routing tables and policy sections. If the frame’s
information appears in the VNS’ virtual routing tables and the
VNS’ policy section contains an entry that verifies that the frame’s
source and the frame’s destination are a valid combination, then
the frame is forwarded to its destination via the 7C03’s
SmartSwitch Bus, and a corresponding entry is written to the
receiving module’s connection table. Otherwise, the frame is
dropped.
1-5